CE Marked – Available Globally
Consistent curing requires periodic monitoring of visible energy intensity or dose. The ACCU-CAL™ 50V radiometer is simple to operate and offers repeatable measurement of visible light. The ACCU-CAL 50V can measure visible light energy emitted from lightguides (3 mm, 5 mm, and 8 mm), flood systems, and conveyors.
With a spectral sensitivity from 400 to 470 nm (blue portion of the visible spectrum), the ACCU-CAL 50V measures intensities from 1 mW/cm2 to 40 W/cm2. A specially designed photo sensor assembly protects the photo sensor from the high temperatures sometimes associated with today’s high-intensity spot lamps.
Looking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchLooking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchBuild a complete solution or find replacement parts for your project
Limited quantities, please submit RFQ for pricing and availability.
5 mm lightguide simulator* with a standard D connection
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Flood to Spot Adapter Kit: Kit includes three lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Lightguide Adapter: Fits 3 mm ID lightguides (5 mm OD)
Lightguide Adapter: Fits 5 mm ID lightguides (7 mm OD)
Lightguide Adapter: Fits 8 mm ID lightguides (10 mm OD)
ACCU-CAL™ 50V for Spot and Flood Lamps and Conveyors: Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case.
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
ACCU-CAL™ 50V for Flood Lamps and Conveyors: Complete radiometer (without lightguide adapters or lightguide simulator*); includes storage/carrying case
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Clearance - ACCU-CAL™ 50V for Spot and Flood Lamps and Conveyors: Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case.
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Limited quantities, please submit RFQ for pricing and availability.
Clearance - ACCU-CAL™ 50V for Spot and Flood Lamps and Conveyors: Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case. Hours: 33011.
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Limited quantities, please submit RFQ for pricing and availability.